National Stock Number · FSC 5925

5925-01-727-9738Circuit Breaker

3 past DLA buys, $1,770.00 to $6,440.26; last May 2026 at $1,770.00.

The part

Item name
Circuit Breaker (CIRCUIT BREAKER)
Federal supply class
5925
NIIN
017279738
End item
M
Unit of issue
each (EA)

Characteristics

From the DLA catalogue
RequirementReply
Body LengthINCHES NOMINAL 2.500
Body WidthINCHES MAXIMUM 2.265
Center to Center Distance Between Terminals Parallel to LengthINCHES NOMINAL 1.940
Distance Between Centerlines of Mounting Facilities Parallel to Body LengthINCHES NOMINAL 2.060
Distance Between Centerlines of Mounting Facilities Parallel to Body WidthINCHES NOMINAL 0.750
End Item IdentificationM55629/6-020
Boss HeightINCHES NOMINAL 0.140
Mounting Surface to Terminal End DistanceINCHES MAXIMUM 2.581
Pole Quantity3
Mounting Facility Type and QuantityTHREADED HOLE(S) 6
Thread Quantity Per Inch32
Maximum Continuous Load Current Rating Per PoleALL LOCATIONS AMPERES AC 1.0
Operating Voltage Type and Rating Per Pole in VoltsALL LOCATIONS AC 240.0
Circuit Protection TypeALL LOCATIONS OVERCURRENT
Trip Release MethodALL LOCATIONS MAGNETIC
Trip Release CharacteristicALL LOCATIONS TIME DELAY
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0
Reset MethodMANUAL
Main Contact Tripping Mechanism TypeTRIP FREE
Manual Actuator Type and QuantityTOGGLE 3
Actuator FunctionTRIP-RESET
Actuator Position DesignationAT EACH POLE
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Internal Trip Release ConfigurationALL LOCATIONS SERIES TRIP
Nominal Thread SizeINCHES 36.0
Switch Location and Position DesignationINTERNAL AT POLE ONE
Trip Delay Time in Seconds Per Rated Continuous CurrentALL LOCATIONS MINIMUM AT 200 PCT 0.150 AND MAXIMUM AT 200 PCT 1.900
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT
Switch Terminal TypeTHREADED STUD
Switch Current Rating and Type in AmpsAC 10.0 AND DC 2.0
Switch Voltage Rating and Type in VoltsAC 250.0 AND DC 50.0
Thread Tolerance ClassINTERNAL 2B
Part Name Assigned by Controlling AgencyCIRCUIT BREAKERS, MAGNETIC, UNSEALED, TRIP-FREE, THREE POLE, AUXILIARY CONTACTS (0.2 TO 50 AMPERES)
Frequency in Hertz400.0
Test Data DocumentSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-55629
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Terminal Type and QuantityTHREADED STUD 6
Specification/Standard DataGOVERNMENT SPECIFICATION 81349--IL-C-55629 TO 6 AND -IL-C-55629

Open DLA RFQs

DLA has no open RFQ for this NSN.

Source: DIBBS

What DLA paid before

DLA bought this part 3 times between Oct 2025 and May 2026, about once every 3 months.

Past buys, newest first
DateQuantityUnit priceWinning CAGE
May 1, 20261$1,770.007YWT4
Dec 3, 20252$1,995.001BRS6
Oct 2, 20252$6,440.2681H24

Approved sources

No DLA RFQ for this NSN lists approved sources.

Catalogue reference part numbers

From the DLA catalogue. Reference part numbers are not approved sources.
CAGEPart numberCompany
81349M55629/6-020LMilitary Specifications Promulgated by Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M
81349MIL-PRF-55629/6Military Specifications Promulgated by Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M

Next steps

Get supplier quotes

Sources

Item name, supply class, end item, characteristics and reference part numbers: DLA PUB LOG®, release of Nov 22, 2026. Past buys: DLA procurement history. Open RFQs, approved sources and unit of issue: DIBBS.